Electric drive system with a frequency converter for gas AVB fans
Description
PZWG 45 kW
The converter is designed for group operation in electric drive systems of fans specifically used for cooling gas after compression. This device features a control algorithm that limits current harmonics, and a range of parameters tailored for the gas transportation technological process.
Specifications:
- Rated power (Pn) at constant moment load for permissible overload current (Ip) of 1.5 In: 45 kW
- Rated output current (In) for power (Pn): 90 A
- Permissible load: 1.5 In 60 per every 10 minutes
- Operational climatic conditions:
– ambient temperature: from -10 °C to +50 °C;
– humidity: from 5% to 95%;
– pressure: from 860 hPa to 1060 hPa;
– explosive environment, dustiness 10 mg/m³, atmosphere category II, permissible humidity up to 98% at a temperature of 25 °C (in accordance with GOST 15150).
- Degree of protection: IP00
- Voltage from the grid: 3 x 380..400 V, 45..66 Hz; other voltage levels are available upon request
- Voltage from the electrical machine: 3 x 380..400 V, 0..400 Hz
- Control:
– scalar U/f (linear or quadratic);
– vector control: (with/without a sensor).
- Indication and control panel with a detachable LCD display
- Built-in PLC controller
- Built-in controller for groups of pumps or fans
- Integrated PID controller
- RS232/RS485 built-in communication module (Modbus)
- Programmable constant speeds
- Motor potentiometer function
- Option of direct connection of the encoder
- Elimination of programmable resonance frequency bands
- Specific shapes and slopes of the speed setting characteristics (linear, “S” curve)
- Torque control capability
- Motor parameter identification
- Programmable structure:
– switchable control options (A, B);
– speed setting (control panel, analog input, PID controller, motor potentiometer, functional block);
– torque setting (analog inputs, functional block);
– start and direction control (control panel, digital input, functional block);
– programmable digital inputs: start, direction, operation lock, external fault, fault rectification;
– programmable digital outputs: ready, operating, fault, no fault, warning, radiator temperature exceeded, current limitation, functional block;
– programmable analog outputs: frequency, rotation speed, output current, voltage, load, arbitrary functional block.
- Operational time measuring
- Locking and diagnostic system
- Keyboard protection with access codes system
- Option of saving parameters for 4 motors
- Predetermined factory parameters
- Built-in LC filter